MATERIALS & APPLICATIONS GUIDE

Deflex has a wide family of thermoplastic polymers, complementary in their properties and benefits.

OUR MATERIALS

Select the material to see detailed information

Guidance table
for the choice of materials

according to its main applications in removable dentures:

APPLICATIONS

MATERIALS

DESCRIPTIONS

APPLICATION

MATERIAL

DESCRIPTION

In order, from the most rigid to the most flexible. Select according to flexibility need of the denture. More rigid dentures are easier to polish and shine.

APPLICATION

MATERIAL

DESCRIPTION

Both with chemical bond with the conventional Acrylic resin, and very low shrinkage.

APPLICATION

MATERIAL

DESCRIPTION

Both with chemical bond with the conventional Acrylic resin, and very low shrinkage.

APPLICATION

MATERIAL

DESCRIPTION

Both with chemical bond with the conventional Acrylic resin, and very low shrinkage.

APPLICATION

MATERIAL

DESCRIPTION

Injectable acetal with tooth-colored retainers. CLASSIC SR and FLUENCE SR can also be used to make translucent pink aesthetic retainers.

APPLICATION

MATERIAL

DESCRIPTION

ACETAL AC is easy to inject and polish. DEFLEX PEEK has greater strength and rigidity.

APPLICATION

MATERIAL

DESCRIPTION

M10 XR and ACRILATO FD can be indicated as coating of metallic structures. DEFLEX PEEK allows to make structures of overdentures to be coated in composite resin, or in self-curing acrylics, or thermo-curable acrylics with a low polymerization temperature.

COLORS

A subtle range of roses satisfies the diverse colors of patient’s gums.

Semi-rigid polyamide

Semi-rigid polyamide

Semi-flexible polyamide

Extra-rigid polymer

Injectable acrylic

Palide pink

Sof pink

Translucent soft pink

Medium pink

Dark pink

Transparent

Injectable acetal

PROPERTIES

ELASTICITY

HIPO-ALLERGENIC

CHEMICAL BOND WITH ACRYLIC

ELASTICITY:

Reference value = 0

HIPO-ALLERGENIC:

YES

CHEMICAL BOND WITH ACRYLIC:

YES*

ELASTICITY:

44%

HIPO-ALLERGENIC:

YES

CHEMICAL BOND WITH ACRYLIC:

SI*

ELASTICITY:

-6%

HIPO-ALLERGENIC:

YES

CHEMICAL BOND WITH ACRYLIC:

NO

ELASTICITY:

-63%

HIPO-ALLERGENIC:

YES

UNIÓN QUÍMICA C/ACRÍLICO:

NO

ELASTICITY:

-6%

HIPO-ALLERGENIC:

YES**

CHEMICAL BOND WITH ACRYLIC:

YES*

ELASTICITY:

+81%

HIPO-ALLERGENIC:

YES

CHEMICAL BOND WITH ACRYLIC:

NO

ELASTICITY:

+125%

HIPO-ALLERGENIC:

YES

CHEMICAL BOND WITH ACRYLIC:

NO

GREATER FLEXIBILITY

GREATER RIRIDITY

(*) Apt for additions and relines using conventional materials and techniques. (**) Meets the requirements of residual content of monomer established in EN ISO 20795-1_2013 (base polymers for dental prostheses)

Injection parameters

TEMPERATURE

INJECTION TIME

HOLDING TIME

AIR PRESSURE

TEMPERATURE:

280ºc +/- 10ºC

INJECTION TIME:

15 min

HOLDING TIME:

1 min

AIR PRESSURE:

6 Kg/cm2 +/- 1
= 86 PSI +/- 14

TEMPERATURE:

305ºc +/- 10ºC

INJECTION TIME:

15 min

HOLDING TIME:

1 min

AIR PRESSURE:

6 Kg/cm2 +/- 1
= 86 PSI +/- 14

TEMPERATURE:

275ºc +/- 10ºC

INJECTION TIME:

15 min

HOLDING TIME:

1 min

AIR PRESSURE:

4,5 Kg/cm2 +/- 0,5
= 64 PSI +/- 7

TEMPERATURA:

260ºc +/- 10ºC

INJECTION TIME:

12 min

HOLDING TIME:

1 min

AIR PRESSURE:

4,5 Kg/cm2 +/- 0,5
= 50 PSI +/- 14

TEMPERATURE:

265ºc +/- 10ºC

INJECTION TIME:

15 min

TIEMPO DE SOSTENIMIENTO:

1 min

AIR PRESSURE:

6 Kg/cm2 +/- 1
= 86 PSI +/- 14

TEMPERATURA:

220ºc +/- 5ºC

INJECTION TIME:

15 min

HOLDING TIME:

1 min

AIR PRESSURE:

4,5 Kg/cm2 +/- 0,5
= 86 PSI +/- 14

TEMPERATURE:

*

INJECTION TIME:

*

HOLDING TIME:

*

AIR PRESSURE:

*

Note: Injection parameters indicated for Deflex injection. For other injection machine consult the manufacturer or supplier of the equipment.
* Injection parameters for OSSIS TI depend on the applied model and injection technique. Refer complete technical indications for different techniques and applications.

COMMERCIAL PRESENTATION

Ready for injection!

Thermo-injectable materials presented in the form of small granuls or tablets.

Pre-dried, colored and packed in aluminum tubes.

Small cartridges: suitable for very small RPD’s and aesthetic retainers
Medium cartridges: for conventional RPD’s, frameworks and occlusal splints
Large cartridges: indicated for full dentures, large RPD’s and overdentures

Available in two different diameters: 22mm y 25mm

Expiration date: 24 months

Why are they packaged in individual cartridges rather than in bulk?
In order to protect the material from moisture and impurities.
In order to optimize dental technician’s times, avoiding drying, cleaning, transfer and closing of tubes.

Diameter 22 mm 

  • Small (x 55 mm)
  • Medium (x 85 mm)
  • Large (x 120 mm)

Diameter 25 mm 

  • Small (x 50 mm)
  • Medium (x 70 mm)
  • Large (x 90 mm)
Hola! queria hacer una consulta
Enviar por whatsapp